Skip to main content

Table 2 Results of automated red blood cell counting on whole slides of thin blood film

From: Automated segmentation of blood cells in Giemsa stained digitized thin blood films

Cell counting

    

sample

#TotalRBC

#RoundCells

#FoundCells

#ApproxCells

AvgRBC diameter μm

I1

59333

17935

40512

886

7.6804

I2

70236

16458

52600

1178

7.5457

I3

43973

23068

20475

430

7.7613

I4

46980

14237

32438

305

7.8404

I5

46090

13670

31918

502

7.5258

C1

57760

18379

38993

388

7.3918

C2

53645

23704

29669

272

6.987

C3

45462

22290

22669

503

7.5385

C4

51605

18108

32674

823

7.2068

C5

58029

16656

41098

275

7.7327

TOTALS

533113

184505

343046

5562

 
  1. Partial and total amount of red blood cells, automatic counting on 500 fields of view per sample. The first five samples are Plasmodium falciparum infected cases I1-I5, samples C1-C5 are non-infected controls.