Figure 11From: Heat transfer model for deep tissue injury: a step towards an early thermographic diagnostic capabilityTemperature distribution in multilayer DTIs. Color coded 2D temperature distributions (top row) and temperature profiles plotted along the line hh’ (bottom row) for multilayer DTIs for an (a) h=8 mm deep lesion with mild inflammation, (b) h=8 mm deep lesion with severe inflammation and an (c) h=3.8 mm deep lesion with mild inflammation. Temperature distributions are computed at 3.5 minutes into the thermal recovery, at a time when the temperature differences of interest are large. Temperature as a function of time during thermal recovery for healthy tissue, multilayer DTIs, ischemia and inflammation for (d) h=8 mm depth and mild inflammation (case (a)), (e) h=8 mm depth, severe inflammation (case (b)) and (f) h=3.8 mm depth, mild inflammation (case (c)).Back to article page