Skip to main content

Table 2 Accuracy of microscopy, latex agglutination, and diamond’s media compared with PCR for detecting T. vaginalis

From: Diagnosis of Trichomonous vaginalis by microscopy, latex agglutination, diamond’s media, and PCR in symptomatic women, Khartoum, Sudan

  

PCR

Accuracy measure (95% CI)

  

Positive

Negative

Total

Microcopy

Positive

251

1

252

Sensitivity

99.2 (97.4-100.0)

 

Negative

2

43

45

Specificity

97.7 (89.3-100.0)

 

Total

253

44

297

Positive predictive value

99.6 (98.1-100.0)

     

Negative predictive value

95.5 (86.1-99.1)

Latex agglutination

Positive

252

5

257

Sensitivity

99.6 (98.1-100.0)

 

Negative

1

39

40

Specificity

88.6 (76.6-95.7)

 

Total

253

44

297

Positive predictive value

98.0 (95.7-99.3)

     

Negative predictive value

97.5 (88.3-100.0)

Diamond’s media

Positive

253

0

253

Sensitivity

100.0 (98.8-100.0)

 

Negative

6

38

44

Specificity

86.4 (73.8-94.3)

 

Total

259

38

297

Positive predictive value

97.6 (95.2-99.1)

     

Negative predictive value

100 (92.4-100.0)