Skip to main content

Comment on: Diagnostic value of miR-186-5p for carotid artery stenosis and its predictive significance for future cerebral ischemic event

I read the article by Lv et al. published in Diagn Pathol 2020. They aimed to investigate the diagnostic value of miR-186-5p for asymptomatic carotid artery stenosis (CAS), and its predictive value for future cerebral ischemic events (CIEs) [1]. Sixty-seven cases with asymptomatic CAS and 60 healthy individuals were recruited. Receiving-operator characteristic (ROC) curve was drawn based on sensitivity and specificity analyses. Kaplan-Meier method was applied for the evaluation of the predictive value of miR-186-5p for the occurrence of CIE. They reported that area under the curve (AUC) was 0.91, with the sensitivity of 89.6% and specificity of 81.7% at the cutoff value of 1.22. Kaplan-Meier method results revealed that high miR-186-5p level was associated with the occurrence of CIEs.

While the article offers insight into the decision that MiR-186-5p is a possible diagnostic biomarker for patients with asymptomatic CAS and predicts the incidence of future CIEs, its conclusion is restricted in three ways. First,knowledge of the reported estimates does not provide overall information on the diagnostic and prognostic value of MiR-186-5p in clinical practice. Diagnostic added value is much more important for clinical purposes than the estimates stated [2,3,4,5]. Diagnostic knowledge is the information required to address the issue, “What is the possibility of the presence or absence of a particular disease given these test results? “ (Research for diagnostic accuracy).

Therefore, diagnostic added value of MiR-186-5p (differences of ROC curves for two diagnostic models with and withour MiR-186-5p) is greatly important in clinical practice. Diagnostic added value of MiR-186-5p may indeed be minimal, although validity estimates may still be excellent. On the other hand, I should mention that as high miR-186-5p level and high degree of carotid stenosis were independent factors for the occurrence of CIEs, one might consider the specificity of these two factors be combined. Combination of the tests are common in clinical practice which increase the specificity and allows to rule in a diagnosis. Second, without determining reliability (precision), we can not judge the diagnostic value of MiR-186-5p. The diagnostic value is determined by the following two parameters: calibration (reliability) and discrimination (accuracy) [2, 6,7,8].

Third, for medical purposes, the global average approach (Kaplan-Meier method) can not be used to predict of an individual based outcome. In addition, for prediction of CIEs, we require data from two separate cohorts or at least one cohort split into two to first build a prediction model and then test our prediction model. Misleading outcomes are generally the main outcome of the research that fails to test the prediction models [9,10,11]. Therefore, reporting association (HR = 4.1) even statistically significant do not gurrantee correct prediction.

I therefore claim that there are certain technical weaknesses and strategies to fix them when determining the predictive and diagnostic value of MiR-186-5p; otherwise, misinterpretation can not be eliminated.

Availability of data and materials

Not applicable.

Abbreviations

miRNAs:

MicroRNAs

CAS:

Carotid artery stenosis

CIEs:

Cerebral ischemic events

ROC:

Receiving–operator characteristic

HRs:

Hazard ratios

AUC:

Under the curve

References

  1. Lv W, Zhang T, Zhao H, He S, Li B, Gao Y, et al. Diagnostic value of miR-186-5p for carotid artery stenosis and its predictive significance for future cerebral ischemic event. Diagn Pathol. 2020;15(1):101.

    Article  CAS  Google Scholar 

  2. Grobbee DE, Hoes AW. Clinical epidemiology: principles, methods, and applications for clinical research. 2nd ed. Burlington: Jones and Bartlett Publisher, United State; 2015.

    Google Scholar 

  3. Sabour S, Ghassemi F. Accuracy, validity, and reliability of the infrared optical head tracker (IOHT). Invest Ophthalmol Vis Sci. 2012;53(8):4776.

    Article  Google Scholar 

  4. Sabour S, Farzaneh F, Peymani P. Evaluation of the sensitivity and reliability of primary rainbow trout hepatocyte vitellogenin expression as a screening assay for estrogen mimics: methodological issues. Aquat Toxicol. 2015;164:175–6.

    Article  CAS  Google Scholar 

  5. Sabour S. Validity and reliability of the 13C-methionine breath test for the detection of moderate hyperhomocysteinemia in Mexican adults; statistical issues in validity and reliability analysis. Clin Chem Lab Med. 2014;52:295–6.

    Google Scholar 

  6. Sabour S. A common mistake in assessing the diagnostic value of a test: failure to account for statistical and Methodologic issues. J Nucl Med. 2017;58:1182–3.

    Article  Google Scholar 

  7. Sabour S. Reproducibility of dynamic Scheimpflug-based pneumotonometer and its correlation with a dynamic bidirectional pneumotonometry device: methodological issues. Cornea. 2015;34(5):14–5.

    Article  Google Scholar 

  8. Sabour S, Rutten A, van der Schouw YT, et al. Inter-scan reproducibility of coronary calcium measurement using multi detector-row computed tomography (MDCT). Eur J Epidemiol. 2007;22(4):235–43.

    Article  Google Scholar 

  9. Sabour S. Obesity predictors in people with chronic spinal cord injury: a common mistake. J Res Med Sci. 2014;19(1):80.

    PubMed  PubMed Central  Google Scholar 

  10. Sabour S, Ghassemi F. Predictive value of confocal scanning laser for the onset of visual field loss. Ophthalmology. 2013;120(6):e31–2.

    Article  Google Scholar 

  11. Sabour S. Prediction of preterm delivery using levels of VEGF and leptin in amniotic fluid from the second trimester: prediction rules. Arch Gynecol Obstet. 2015;291(4):719.

    Article  Google Scholar 

Download references

Acknowledgements

Not applicable.

Funding

None.

Author information

Authors and Affiliations

Authors

Contributions

SS wrote and revised the manuscript. The author read and approved the final manuscript.

Corresponding author

Correspondence to Siamak Sabour.

Ethics declarations

Ethics approval and consent to participate

Not applicable.

Consent for publication

All study subjects gave written informed consent for publication.

Competing interests

The author declares that he has no competing interests.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Sabour, S. Comment on: Diagnostic value of miR-186-5p for carotid artery stenosis and its predictive significance for future cerebral ischemic event. Diagn Pathol 15, 138 (2020). https://doi.org/10.1186/s13000-020-01055-2

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s13000-020-01055-2

Keywords